The UTC Interlogix RCR-REX-B is a dual technology, request-to-exit sensor used for secure door egress and door access control. The sensor combines the power of passive infrared and Doppler rangecontrolled radar technologies to provide the industrys most secure request-to-exit sensor.

With the RCR-REX-B, dual technology requires that both the units PIR sensor and RCR sensor detect intrusion activity in order to trigger the internal relay. For maximum protection, adjust the radar so that the curtain is above the oor; objects slipped under the door will not activate the sensor, making it virtually impossible to defeat.

Depending on the settings chosen by the installer, when the RCR-REX-B's sounder is turned on, it produces an audible tone to warn of door-open-too-long (DOTL). Closing the door silences the sounder, while new movement restarts the timer and resets the sounder. A beeping tone will sound at the end of the external input signal if the door is open.

UPC: 046188123667
Also known as: SR-RCRREXB, GES-RCRREXB, RCRREXB

Technical Specifications:
  • Range: Depth 3 to 15 ft. (0.9 to 4.57 m) adjustable, Width 7.9 ft. (2.4 m), PIR 15 ft. (4.6 m), adjustable
  • Radar Frequency: 5.8 GHz
  • Wire Gauge: AWG 14 to 22 (18 to 22 recommended)
  • Dimensions (HxWxD): 1.76" x 7.395" x 1.85" (45 mm x 188 mm x 47 mm)
  • Mounting Height 7 to 15 ft. (2.13 to 4.57 m) typical
  • Color: Black
  • Housing Material: ABS plastic
  • Weight: 9.2 oz. (261 g)
  • Tamper Output: 50mA @ 30VDC
  • Alarm Output: DPDT (Form C)
  • Max. Loop Rating: 2A @ 30VDC
  • Loop Type: Open or Closed
  • Time Delay: 1/2, 1, 2, 4, 8, 16, 32, 64 sec. at ± 10%, selectable
  • Current: 23mA typical, 28mA max. @ 12VDC; 15mA typical, 17mA max. @ 24VDC; 31mA typical, 38mA max. at 12VAC; 26mA typical, 29mA max. at 24VAC
  • Voltage: 12 to 30VAC/VDC


For more information about the UTC (Formerly GE Security/Sentrol) RCR-REX-B, please contact us.
  • Color: Black
  • Dual relay outputs
  • Wall or ceiling mount
  • Built-in adjustable sounder for door position monitoring
  • Swing open design allows easy adjustment
  • Includes mask for easy adjustment of PIR field of view
  • Tamper switch detects device open
  • Incorporates two Form C output relay contacts
  • Proprietary dual technology—request-to-exit uses both RCR and PIR to detect intruders
  • Optional single gang wall plate