­

Silent Knight 5496 Intelligent Distributed Power Module

  • MPN: 5496
  • JMAC ID: 200003675
$455.54
In Stock
  • Expedited Shipping Available Expedited Shipping Available
  • Need it Tomorrow?
    Need it Tomorrow?
    Select the NEED IT FAST shipping option at checkout and a member of our team will contact you promptly with any available Expedited Shipping options once we receive your order.
JMAC_ID:
200003675
df_manual_boost:
1.90
The SILENT-KNIGHT-5496 is a 6 amp notification power expander that provides its own AC power connection, battery charging circuit, and backup battery for use with fire and security controls such as the IntelliKnight Model 5808 Fire Control/Communicator.

The 5496 is the cost-effective solution for powering notification appliances required by the Americans with Disabilities Act (ADA) and has built-in ANSI cadence pattern, which can upgrade older control panels that lack cadence capability.

UPC: 783196010618
Also known as: SK-5496

Technical Specifications:
  • Dimensions: 12.25” W x 16” H x3” D (30.88 Wx 40.64 H x7.62 D cm)
  • Battery charging capacity: 35.0 AH
  • Notification circuit output: 20.4 to 27.3 VDC, 3.0 amps each, 4.7k EOL resistor required on each Class B circuit
  • Amps per output circuit: 3.0 (6.0 amps total)
  • Output configuration: 2 Class A (Style Z), 4 Class B (Style Y) (1 Class A & 2 Class B)
  • Notification/Aux.Power circuits: 4
  • Current: Standby 40 mA, Alarm 160 mA
  • Output: 24 VDC at 6 amps
  • AC Input: 120 VAC at 2.7 A


For more information about the Silent Knight 5496, please contact us.
  • • Lightweight design adds to ease of installation and reduces shipping costs
  • ANSI Cadence pattern output capability built-in
  • UL 864,1481 & 1971 listed
  • AC loss delay option shuts off power to non-essential high-current accessories like magnetic door holders
  • Communicates to the FACP via 4-wire SBUS (wire runs up to 6000 ft)
  • Ground fault detector
  • 3 amps per output circuit
  • NACs are programmable as Notification Appliance Circuits, or as auxiliary power to be used as constant, resettable, or door holder power
  • Four power-limited notification outputs; 2 Class A or 4 Class B, or 1 Class A and 2 Class B
  • 24 VDC filtered output voltage
  • Built-in synchronization for appliances from AMSECO, Gentex®, Faraday, System Sensor®, and Wheelock®
  • Power supply’s advanced switch mode design reduces damaging heat and manages power up to 50% more efficiently than other systems
  • UL Listed for 6 amps of notification power

2 Reviews

  • 5
    SILENT-KNIGHT-5496

    Posted by 129963 on Jul 27th 2018

  • 5
    SILENT-KNIGHT-5496

    Posted by 85610 on Jun 21st 2015

Live Chat