Macurco TX-6-HS Macurco Hydrogen Sulfide Detector, Controller and Transducer, 12-24 VAC or 12-32 VDC, Dark Gray


  • Also known as: TX6HS, MA-TX6HS

  • The Macurco TX-6-HS s a low voltage, dual relay, Hydrogen Sulfide (H2S) detector, controller and transducer used to measure the concentration of H2S and provide feedback and automatic exhaust fan control to help reduce H2S concentrations in refineries, pulp and paper mills, waste disposal or other commercial applications.

    The TX-6-HS is a low level meter capable of displaying from 0-50 ppm of Hydrogen Sulfide and has selectable 4-20 mA output, buzzer and digital display options.

    The TX-6-HS is also available in white.
    Features:
    • 12-24 VAC or 12-32 VDC input
    • 5A SPDT Fan control relay
    • 0.5A N.O. or N.C. Alarm Relay
    • Selectable Fan and Alarm Relay Actuation Settings
    • Digital Display (0-50ppm of H2S), Internal Buzzer
    • Coverage Area: 900 sq. ft.
    • 4-20mA current loop


    Technical Specifications:

    • Power: 3W (max) from 12 to 24 VAC or 12 to 32 VDC
    • Current @ 24 VDC: 75 mA in alarm, 50 mA fan relay on and 23 mA stand by
    • Shipping Weight: 1 lb (0.45 kg)
    • Dimensions: 4-1/2" x 4" x 2-1/8" (11.4 cm X 10.2 cm X 5.4 cm)
    • Color: Dark gray
    • Connections: plugs/terminals
    • Mounting box: (not included) 4x4 electric
    • Fan relay: 5 A, 240 VAC, pilot duty, SPDT, latching or non-latching
    • Fan relay actuation: selectable at OFF, 1, 2, 3, 4, 5, 6, 7, 8 (default),
    • 9, 10 , 11, 12, 13, 14, 15, 16, 17, 18, 19, 20 ppm
    • Fan Delay Settings of 0, 1, 3 (default), 5 and 10 minutes
    • Fan Minimum Runtime settings are OFF (default), 3, 5, 10 or 15 minutes
    • Alarm relay: 0.5A 120 V, 60 VA
    • Alarm relay actuation: selectable N.O. default or N.C. TX-6-HS Rear View
    • Alarm relay settings: OFF, 5, 10, 15, 20 (default), 25, 30, 35, 40, 45, 50 ppm H2S
    • Current Loop, 4-20 mA for 0-50 ppm H2S
    • Operating Environ: 0F to 125 F (-18C or above 52C).10 to 90% RH


    UPC: 783748834600

    Average rating: 4.5, based on 2 reviews


    For more information about the Macurco TX-6-HS, please contact us.

    Share your knowledge of this product with other customers... Be the first to write a review

    Browse for more products in the same category as this item:

    Macurco > Toxic Gas Detectors
    Macurco
    Fire & Life Safety > Gas Detectors
    Fire & Life Safety > Gas Detectors > Toxic Gas Detectors
    Fire & Life Safety