The B5512 Control Panel integrates intrusion and residential fire, providing one simple user interface for both systems. The B5512 provides up to 48 individually identified points that can be split into 4 areas.
The control panel can communicate through its built-in Ethernet port (not applicable to E control panels), or through compatible plug-in modules that can send events over the public switched telephone network (PSTN) or over cellular network communications.
With the B5512, you can monitor doors, windows, and motion within areas like showrooms or those that hold inventory. Each user can have a personalized passcode, a wireless keyfob, and a credential to control the system.
Use programmable authority levels with restricted privileges to provide service, security, and cleaning personnel with full or limited access. Use the three programmable outputs (expandable up to 43) to turn on lights or lock and unlock doors. Users can: Turn on the system to secure the stockroom while you conduct daily business; Perform tests to ensure your system is working properly; Set your system to alarm immediately if a door opens.
The B5512 Control Panel combines the intrusion and residential fire systems into a single user interface. The B5512 offers up to 48 uniquely identifiable points that can be divided into four distinct areas. The control panel can communicate via its Ethernet port (not applicable to "E" control panels) or via compatible plug-in modules that can send events over the public switched telephone network (PSTN) or cellular network communications. With the B5512, you can monitor doors, windows, and movement in areas such as showrooms and warehouses. Each user can control the system with a personalized passcode, a wireless keyfob, and a credential.
UPC: 800549646161
Also known as: BOS-B5512
Technical Specifications:
- Voltage (AC): CX4010 Plug-in Transformer (18 VAC 22 VA 60 Hz) or ICP‑TR1822‑CAN Plug‑in Transformer (110 VAC primary, 18 VAC 22 VA secondary)
- Voltage (operating): 12 VDC nominal
- Output (auxiliary, continuous power, and switched auxiliary combined): 800 mA at 12 VDC nominal
- Output (alarm): 1.3 A at 12 VDC
- Current draw (maximum): Idle 125 mA; Alarm 155 mA
- SKEDs: 5
- IP cameras: 4
- RF points: 40
- Programmable outputs: 43 (3 on-board, up to 40 off-board and virtual)
- Points: 48 (8 on-board, up to 40 off-board and virtual)
- Passcode users: 50, plus 1 Installer passcode
- Events: Up to 255
- Custom functions: 4
- Areas: 4
- Temperature (operating): +32°F to +122°F (0°C to +49°C)
- Relative humidity: 5% to 93% at +90°F (+32°C), non-condensing
- Ethernet: 10/100 full duplex (N/A for “E” control panels)
|
For more information about the Bosch Security B5512, please
contact us.